For air purification,
Biozone has developed a technology we call PureWave
that combines the science of ultraviolet germicidal
light waves, purifying hydroxyls, activated oxygen, and
photo-ionization. What makes this technology important
and unique is that it unites four of the most accepted
and powerful methods for destroying contaminants, with
the resulting synergy producing a stronger process than
the sum of the individual methods.
The result of this perfect marriage of science and
electronics is the "ultimate" air purifying
process.
Ultraviolet Light (UVGI)
Biozone's technology revolves around the power and
versatility of UV lightwaves. A basic characteristic of
UV lamps is that the larger the lamp, the greater the
output of germicidal ultraviolet germicidal irradiation
(UVGI). But larger or longer UV lamps that create ozone
can also produce too much ozone. Working with the
world's premier manufacturer of UV lamps, Biozone has
developed a high-purity, split lamp that produces
significantly more UVGI but without increased ozone
production. Also important is the ability our units have
to maintain consistent UV wavelengths. Our lamps can
produce UV light at the 185 nanometer (nm) and 254nm
wavelengths. This combination of wavelengths is
necessary for the photoxidation of organic compounds. Read
more.
The specific wavelength
of 254nm is most effective at inactivation of harmful
contaminates. As an airborne microorganism enters the
Biozone Air Purification Chamber, the UV light
penetrates the organism’s membrane and alters its
genetic material (DNA). With altered DNA, the
microorganism will no longer be able to
reproduce—rendering it microbiologically dead and,
therefore, harmless. Due to the short lifespan of
most microorganisms, once they lose the ability to
reproduce, the population of them in the air diminishes
rapidly and dramatically.
Photolic Ozone -
Guaranteed Control
While most manufacturers
of ozone air purifiers use the older, corona
discharge (high voltage electricity) method to
create ozone, our unique UV lamp technology also
naturally controls ozone levels by producing wavelengths
that produce photolic ozone and other wavelenths that
control its level by naturally destroying excess ozone.
Like ozone, UVGI destroys bacteria, viruses, and fungi
and has been used in medical facilities for years for
those exact purposes for nearly three-quarters of a
century.
Hydroxyl Radicals
(OH)
The combination of
photolic ozone, UVGI, and moisture (humidity) produces
powerful oxidants known as hydroxyl
radicals. These molecules have been described as
"the single most important cleansing agent in the
earth's atmosphere." (Read
related article). They break down hazardous organic
compounds and are a major catalyst in the chain reaction
necessary for contaminant oxidation.
Negative Ions
In addition to these highly effective purification
methods, Biozone units produce negative ions by means of
a patent-pending method that dramatically accelerates
the production of negative ions via ultraviolet
wavelengths.
Read more.
Photolic Ozone
Ozone generators have been used for over a hundred
years for purification and sanitation purposes in a wide
variety of applications. Ozone's properties as a
bactericide, viricide, fungicide and deodorizer are
well-accepted by the scientific community. Industry as
well as the general public have eagerly accepted
ozonation as a method of water and air purification.
However, it is also well-established that exposure to
high levels of ozone can be harmful to health, and in
particular can be a respiratory irritant. This has led
to a controversy as to the safety of such ozone
generators for general public use. There is no consensus
as to when ozone levels become harmful to humans, but
based on available research, regulatory agencies such as
the FDA have set safe levels at .05 ppm (parts per
million) for continual exposure. OSHA has set 0.1 ppm as
a maximum for 8 hour exposures. Other agencies and
organizations have similar recommendations. Previously,
all ozone generators used for air purification had the
potential to produce ozone levels well over these
recommended levels. To combat this problem, some
manufacturers of portable ozone air purifiers have
introduced models with ozone sensors that automatically
shut off the units when ozone levels rise above a
prescribed limit. While this is a step in the right
direction, these devices are not foolproof, nor do they
seem to work well in all size environments. They also do
little or nothing to control the "blasting" of
high concentrations of ozone that occur (usually due to
power fluctuations, but there are other causes) when
operating.
Biozone has developed another method to ensure
safe ozone levels called SafeZone. It will not
allow the accumulation of ozone in your air to exceed
recommended, safe levels. It is a fail-safe method.
SafeZone does not rely on electronic gadgetry or
inexpensive sensors, but combines the science of
ultraviolet radiation, atom disassociation, quantum
yield, and optimization of unit geometry. In practical
terms, this means as the ozone level in an environment
begins to rise, the machine will automatically reduce
the amount of ozone being produced, thereby keeping the
accumulation at low levels. There is no longer a reason
to have concern about the potential harmful effects of
too much ozone. Biozone's air purifiers provide all the
wonderful, powerful benefits of ozone but with none of
the worry associated with previous ozone devices. If you
love the pure air at Yosemite National Park, Lake Tahoe,
or Sequoia National Park, then you will love the results
of the SafeZone method.
Biozone's Research and Development has also produced
a state-of-the-art electronics module to power the
PureWave System. This advanced engineered electronics
package is a solid-state unit with constant wattage
circuitry for greater electrical efficiency and for the
support of consistent output and long life. In addition,
the electronics design is 12VDC resulting in one of the
safest devices in the market and hence our trademark,
SafeVolt. The SafeVolt 12VDC system is a vast electrical
improvement over ozone units using the corona discharge
method of creating ozone which requires 5,000 - 10,000
volts of electricity. The added advantage of Biozone's
12VDC system is that it is easily used all over the
world. No more worry about countries varying electrical
systems using 110VAC or 220VAC or 240VAC. A simple AC/DC